Fluke 107 Pocket Digital Multimeter
Fluke 107 Pocket Digital Multimeter — 2Fluke 107 Pocket Digital Multimeter — 3Fluke 107 Pocket Digital Multimeter — 4Fluke 107 Pocket Digital Multimeter — 5Fluke 107 Pocket Digital Multimeter — 6Fluke 107 Pocket Digital Multimeter — 7
Fluke

Fluke 107 Pocket Digital Multimeter

Model: 107

⬇ Download datasheet (PDF)
The Fluke 107 is a compact, palm size easy-to-use digital multimeter made to fit the way you work. It is the perfect first-pass
Ask on WhatsApp

Details & specifications

Key Features

  1. CAT III 600 V safety rating
  2. Current and voltage measurements
  3. Measures resistance and continuity to check for broken wires
  4. Data hold and backlit display to keep you working safe and fast


 

Fluke 107 comes ready to work

The Fluke 107 comes with a TL75 Hard Point™ Test Lead Set. It’s one pair (red, black) of 48 inch (1.22 meter) test leads with right-angle, shrouded banana plugs. The meter also includes a SmartStrap™ intelligent magnetic multi-purpose lanyard that lets you hang the Fluke 107 from any ferrous surface or support the meter at an angle for easy viewing.

What's in the box:

  1. Fluke 107 palm-sized digital multimeter
  2. (1 pair) TL75 Hard Point™ Test Leads
  3. (2) AAA batteries (installed)
  4. SmartStrap™ intelligent magnetic, multi-purpose lanyard
  5. 2-year warranty.

Specifications: Fluke 107 Pocket Digital Multimeter

Accuracy is available for one year after calibration, operating from 18 °C to 28 °C and relative humidity from 0% to 75%. The format of the accuracy specification is: ± ([% of reading] + [least significant digit])

Precision specifications

AC voltage(40 Hz to 500 Hz)1RangeResolutionAccuracy
6.000 V60.00 V600.0 V0.001 V0.01 V0.1 V1.0 % + 3
DC voltage6.000 V60.00 V600.0 V0.001 V0.01 V0.1 V0.5 % + 3
Exchange millivolts600.0 mV0.1 mV3.0 % + 3



Diode test22.000 V0.001 V10 %



Resistance(ohm)400.0 Ω4.000 kΩ40.00 kΩ400.0 kΩ4.000 MΩ40.00 MΩ0.1 Ω0.001 kΩ0.01 kΩ0.1 kΩ0.001 MΩ0.01 MΩ0.5 % + 30.5 % + 20.5 % + 20.5 % + 20.5 % + 21.5% + 3
Capacitor350.00 nF500.0 nF5.000 μF50.00 μF500.0 μF1000 μF0.01 nF0.1 nF0.001 μF0.01 μF0.1 μF1 μF2 % + 52 % + 55 % + 55 % + 55 % + 55 % + 5
Frequency4 Hz(10 Hz – 100 kHz)50.00 Hz500.0 Hz5.000 kHz50.00 kHz100.0 kHz0.01 Hz0.1 Hz0.001 kHz0.01 kHz0.1 kHz0.1 % + 3






Duty cycle41 % to 99 %0.10 %1 % typical case5















AC current(40 Hz - 200 Hz)4.000 A10.00 A0.001 A0.01 A1.5 % + 3












DC4.000 A10.00 A0.001 A0.01 A1.5 % + 3













  1. All AC current, frequency, and duty cycle are specified from 1% to 100% of the range. Input values below 1% of range are not specified.
  2. Typically, the open circuit test voltage is 2.0 V and the short circuit current is < 0.6 mA.
  3. The parameters do not include errors due to test lead capacitance and capacitor substrate (up to 1.5 nF in the 50 nF range).
  4. All AC current, frequency, and duty cycle are specified from 1% to 100% of the range. Input values below 1% of range are not specified.
  5. Typically, the frequency is 50 Hz or 60 Hz and the duty cycle is 10% to 90%.
FeaturesOverload protectionInput impedance (nominal value)Common mode rejection ratioNormal mode rejection ratio
AC voltage600 V 1>10 MΩ <100 pF 2>60 dB at 50 Hz or 60 Hz at DC current−
Exchange millivolts600 mV>1M, <100 pF>80 dB at 50 Hz or 60 Hz−
DC voltage600 V 1>10 MΩ <100 pF>100 dB at 50 Hz or 60 Hz at DC current>60 dB at 50 Hz or 60 Hz
  1. Up to 6 x 105 V Hz
  2. For medium voltage (alternating current), the input impedance is approximately 1 MΩ.


Customer reviews

No reviews yet.